Civic Result MapsU.S. election equipment evidence

Source-linked configuration dossier

ES&S EVS 6.4.0.0 / DS950

A separate source-linked dossier for the certified DS950 central-count scanner/tabulator, including firmware and hardware revisions, documented motherboard and storage changes, output-transport firmware, central-count cart, and certified UPS alternatives.

Federal certificate ESSEVS6400VVSG 1.0VSTL: Pro V&V, Inc.Editorial: published r3
Components10all source-linked
Hardware facts20 explicit unknowns
Change records2field status kept separate
Findings/statuses1version-scoped
Archived sources5local hash verified
Do not collapse evidence scopes.

A certified component list does not prove what a jurisdiction installed. A jurisdiction system-version listing does not prove device firmware, configuration-change adoption, internal parts, or power topology.

Selectable schematic

Orthographic component explorer

Use the accessible component list as the source of truth. The optional 3D view mirrors that selection.

Components10 records
illustrative not to scale
Reference: DS950 manufacturer product form on the certified Central Count Cart category
2D evidence view is active

Open the lightweight local 3D schematic when useful. It is opt-in on every screen size.

certified configuration
certified component

DS950 scanner and tabulator assembly

The certified scope describes a central scanner/tabulator that scans both sides of ballots or vote-summary cards in any of four orientations.

Models: DS950

Hardware revisions in source: 1.1

Certified DS950 firmware: 4.3.0.0

Linked findings: No anomalies reported in the EVS 6.4.0.0 certification campaign

Hardware and interfaces

firmwareconfirmed
Certified DS950 firmware

4.3.0.0

EVS 6.4.0.0 DS950 hardware 1.1

This is the certified configuration version, not a field reading or a claim about later releases.

usbdocumented partial
Protected USB access

Manufacturer states USB ports are behind clear lockable, sealable doors

DS950 manufacturer product family

This establishes an access-control feature, not a connector count or the sealed condition of a field unit.

The certified revision and firmware are configuration records, not unit-level observations.

Sources for this selection

Network configuration evidence

Documented paths, controls, and unknowns

Expected, documented, and observed configurations remain separate. Physical port capability is not treated as an active connection.

Safe public evidence boundaryReviewed 2026-07-21

The EVS 6.4.0.0 Pro V&V report states that DS950, DS850, and DS450 results were transmitted to the EMS through a closed local area network during accuracy testing. The EAC scope includes the central tabulator, Electionware infrastructure, and a minimum-1-Gb network switch, but it does not establish a jurisdiction's live switch, port, or addressing configuration.

This view publishes only the laboratory-supported closed-LAN result path and its source limits. It excludes IP addresses, credentials, keys, database details, switch settings, VLANs, hostnames, device identifiers, and site-specific routing.
1 sourced configuration view2 source imagesNo field-observed topology collected
expected layervstl test configurationdocumented partial

EVS 6.4.0.0 central-tabulator closed-LAN test path

Pro V&V tested DS950 result transmission over a closed LAN to the EMS. The EAC scope separately lists a minimum-1-Gb switch among certified COTS hardware. The public passages support the system-level path but not every physical connector or a field installation.

Topologyclosed wired lan
Select a nodeHighlights its documented paths
documentedClosed LAN

The VSTL report explicitly identifies the DS950 central-tabulator result path as a closed local area network.

not publicly establishedPublic-network path

The reviewed DS950 accuracy-test passage does not describe a public-network transmission path.

not publicly establishedField network state

No jurisdiction switch, port, address, enabled-service, or cable record is established in this dossier.

Operational details withheld

No addresses, credentials, keys, database identifiers, switch settings, VLANs, hostnames, device identifiers, or site routing is collected or displayed.

A VSTL accuracy-test topology is not proof that a jurisdiction connected a DS950, used the listed switch, or transmitted results over a network in a particular election.
Source diagrams and pagesExpand any image; scope and caveats stay attached.
Evidence gapsUnknowns stay explicit and source-bounded.

Version evidence

Last sourced observations

“Last” means latest in this reviewed source package, not a live device reading or the newest product-family release.

VSTL + EAC change control

Configuration change history

These are source-linked certification and change records. Field deployment remains separate and unknown unless explicitly documented.

EVS 6.4.0.0 DS950 hardware modification setEAC approved 2023-08-18

The scope records an updated Kontron motherboard with DRAM/TPM capabilities, updated PC power supply, second-source smart-card reader, and M.2 hard drive.

VSTL
Pro V&V, Inc.
Dossier relationship
included in certified evs 6400 configuration
Field deployment
unknown

This groups certification modifications and is not a claim that one field service event installed them together.

ECO 1151EAC approved 2023-08-18

ECO 1151 updates DATAWIN transporter firmware so the output tray begins lowering sooner, providing more opportunity for incoming ballots to lay flat if a jam occurs.

VSTL
Pro V&V, Inc.
Dossier relationship
baseline eco certified with evs 6400
Field deployment
unknown

The de minimis ECO is certification history, not evidence of a jam, field update, or election impact.

Findings and public status

Tests, limitations, and listing gaps

Neutral finding types replace a generic “bugs” bucket so affected versions and source scope remain visible.

vstl test campaign resultnone reported in test campaign

No anomalies reported in the EVS 6.4.0.0 certification campaign

Pro V&V reported no anomalies during EVS 6.4.0.0 testing and recommended certification after the system met applicable VVSG 1.0 requirements.

A bounded test result is not evidence that every fielded DS950 is defect-free or a claim about misconduct or outcomes.

Power evidence

Backup supply and runtime

Named power equipment is rendered exactly as sourced. Missing capacity and runtime remain explicit instead of being inferred from another device or installation.

confirmed

DS950 power / backup supply

The certified COTS hardware table names two CyberPower UPS alternatives that apply to the DS950.

Supply type
external uninterruptible power supply
Manufacturer
CyberPower
UPS model
OR1500PFCLCD; CP1500PFCLCD
Capacity
Not specified in reviewed source
Runtime
Not specified in reviewed source
The sources do not state a DS950 workload runtime or establish option selection, battery age, capacity, or condition.

Deployment evidence

Dated jurisdiction observations

Deployment records remain at their documented grain. A system-level observation does not establish unit components, firmware, change adoption, or power configuration.

not collected

No reviewed deployment observation in this dossier

The source package currently establishes a certified configuration and test history, but no dated jurisdiction-level use record.

Absence from this catalog is not evidence that the system is unused. Deployment claims require a separately reviewed state or local source.

Jurisdiction context

Where this equipment appears in 2024 records

These jurisdiction rows are third-party administration context. A product-family name supports only that named family at the reported jurisdiction grain. A manufacturer match does not establish that a particular dossier model, component, firmware version, or certified configuration was deployed.

Manufacturer context1,509 locales40 states; vendor only, not proof of this exact model
Map resolution1,504 pinned5 source rows open at state scope
53 matching sourced recordsPage 1 of 3

Provenance

Archived source manifest

Each local artifact is checked against its reviewed SHA-256 during catalog validation.

federal official

EVS 6.4.0.0 certification record

U.S. Election Assistance Commission

5ad71e34c04a2ccbfc1b57aa4cadbf44ab1a27247afa5d985793ec7eab820b7cdata/equipment-sources/eac-evs-6400.htmlReviewed revision: eac-evs-6400-record@2026-07-19Open official source
federal official

EVS 6.4.0.0 Certificate and Scope of Conformance

U.S. Election Assistance Commission

18ac832291345ff96e5bfe8bd63ede7d1af2ed9a4387b8bf47f0b9fb2564ebaedata/equipment-sources/eac-evs-6400-certificate-scope.pdfReviewed revision: eac-evs-6400-scope@2026-07-19Open official source
manufacturer primary

DS950 high-speed scanner and tabulator product page

Election Systems & Software

001a17e5b579bc94a0efd15871c1d0c8565aa58dd135df03344163687e62fba3data/equipment-sources/ess-ds950-product-page.htmlReviewed revision: ess-ds950-product-page@2026-07-20Open official source
manufacturer primary

DS950 official catalog photograph

Election Systems & Software

0b6b919d9c91b8447f56c866174ce647c816a16c88dbc73d5c4c0497796e6c59data/equipment-sources/ess-ds950-reference-photo.jpgReviewed revision: ess-ds950-reference-photo@2026-07-20Open official source
eac accredited vstl

ES&S EVS 6.4.0.0 Certification Test Report TR-01-01-ESS-2023-01.03

Pro V&V, Inc.

cfc04d88fd4be79cb793eb18ab940b01be1295426c14d43062081acd69a6ba84data/equipment-sources/provv-evs-6400-test-report.pdfReviewed revision: provv-evs-6400-test-report@2026-07-19Open official source