Clear Ballot ClearVote 2.5 / ClearAccess

A source-linked dossier for the ClearAccess ballot-marking configuration within EAC-certified ClearVote 2.5, including named COTS components, explicit external UPS options, certified software observations, and Pro V&V test findings.

Federal certificate CBG-CV-25VVSG 1.0VSTL: Pro V&V, Inc.Editorial: published r5
Components9all source-linked
Hardware facts82 explicit unknowns
Change records3field status kept separate
Findings/statuses4version-scoped
Archived sources8local hash verified

Version evidence

Last sourced observations

“Last” means latest in this reviewed source package, not a live device reading or the newest product-family release.

certified assertion2025-11-19

EAC-certified ClearAccess software

2.5.6

This is the software version in the certified ClearVote 2.5 configuration, not a live device reading or a claim about the newest ClearVote release.

VSTL + EAC change control

Configuration change history

These are source-linked certification and change records. Field deployment remains separate and unknown unless explicitly documented.

SW-10275EAC approved 2025-11-19

ClearAccess automatically rolls the system log when more than 1,000 log entries are present to reduce performance risk.

VSTL
Pro V&V, Inc.
Dossier relationship
included in certified 25 configuration
Field deployment
unknown

The change appears in the submitted ClearVote 2.5 certification modification set. It does not establish installation on a particular fielded unit.

SW-10691EAC approved 2025-11-19

ClearAccess and ClearCast received minor libssl and OpenSSL version updates in the submitted modification set.

VSTL
Pro V&V, Inc.
Dossier relationship
included in certified 25 configuration
Field deployment
unknown

This is certification configuration history, not evidence of a field update, patch installation date, or current exposure on any unit.

TR-DEF-556EAC approved 2025-11-19

The ClearAccess 2.5.5 write-in controls did not meet specified touch-area dimensions; the report records the corrected 2.5.6 interface.

VSTL
Pro V&V, Inc.
Dossier relationship
resolved during certification campaign
Field deployment
unknown

This is a test-campaign deficiency and resolution, not evidence that version 2.5.5 was used in a public election.

Findings and public status

Tests, limitations, and listing gaps

Neutral finding types replace a generic “bugs” bucket so affected versions and source scope remain visible.

resolved test deficiencyresolved in clearaccess 2 5 6

ClearAccess 2.5.5 write-in controls were undersized

Pro V&V reported that the write-in menu button dimensions and spacing in ClearAccess 2.5.5 did not meet the cited VVSG requirement and documented corrected dimensions and keyboard options in 2.5.6.

This is a certification-test finding with a reported resolution. It is not evidence that the deficient build was deployed in an election.
certification change noteupdate recorded for cve 2022 0778

OpenSSL libraries updated in the submitted modification set

The Pro V&V test plan identifies the ClearAccess and ClearCast libssl/OpenSSL update as a bug change addressing CVE-2022-0778.

The record describes the submitted certified configuration. It is not a field vulnerability scan, a current security assessment, or evidence of exploitation.
test campaign resultcertified after documented resolutions

One anomaly and multiple deficiencies were documented during testing

The final Pro V&V report describes one ClearMark anomaly with no determined root cause and lists test deficiencies with reported corrective actions before recommending certification of the submitted system.

This system-level summary is not a claim that ClearAccess caused the ClearMark anomaly, that findings occurred in the field, or that no other defects exist.
historical scope notenot fielded as of 2024 08 02 test plan

The modification had not been fielded when the 2024 test plan was written

The Pro V&V test plan stated that the ClearVote 2.5 modification had not been fielded for use as of the plan date.

This is a historical pre-certification statement. Do not infer that ClearVote 2.5 remained undeployed after certification or is not deployed today.

Power evidence

Backup supply and runtime

Named power equipment is rendered exactly as sourced. Missing capacity and runtime remain explicit instead of being inferred from another device or installation.

confirmed

ClearAccess power / backup supply

The certified ClearVote 2.5 scope names three external UPS options for ClearAccess. The reviewed sources do not provide a ClearAccess load-specific capacity or runtime claim.

Supply type
external uninterruptible power supply
Manufacturer
CyberPower; APC
UPS model
PR1500RT2U; SMT2200C; SRT1500RMXLA
Capacity
Not specified in reviewed source
Runtime
Not specified in reviewed source
Confirmed means the models appear in the certified configuration, not that every jurisdiction uses one, that all are used together, or that battery health and runtime are known for a fielded setup.

Deployment evidence

Dated jurisdiction observations

Deployment records remain at their documented grain. A system-level observation does not establish unit components, firmware, change adoption, or power configuration.

not collected

No reviewed deployment observation in this dossier

The source package currently establishes a certified configuration and test history, but no dated jurisdiction-level use record.

Absence from this catalog is not evidence that the system is unused. Deployment claims require a separately reviewed state or local source.