Clear Ballot ClearVote 2.5 / ClearCount

A separate source-linked dossier for the ClearCount 2.5 central-count system, which uses a CountServer, ScanStations paired with certified COTS scanners, CountStations, a closed wired network, and an external UPS.

Federal certificate CBG-CV-25VVSG 1.0VSTL: Pro V&V, Inc.Editorial: published r3
Components7all source-linked
Hardware facts40 explicit unknowns
Change records1field status kept separate
Findings/statuses1version-scoped
Archived sources7local hash verified

Version evidence

Last sourced observations

“Last” means latest in this reviewed source package, not a live device reading or the newest product-family release.

VSTL + EAC change control

Configuration change history

These are source-linked certification and change records. Field deployment remains separate and unknown unless explicitly documented.

SW-11911 / SW-11928EAC approved 2025-11-19

The ClearVote 2.5 modification list records corrections so the ballot tabulator properly handles a card with contests only on its back side.

VSTL
Pro V&V, Inc.
Dossier relationship
included in certified 25 configuration
Field deployment
unknown

This is certification configuration history. It does not establish a field occurrence, election impact, or update date for any jurisdiction.

Findings and public status

Tests, limitations, and listing gaps

Neutral finding types replace a generic “bugs” bucket so affected versions and source scope remain visible.

certification change notecorrection included in certified 2 5

Back-side-only contest card tabulation correction

The submitted modification list identifies a correction for cards with contests only on the back side.

The record does not quantify occurrence, identify a fielded version, or establish an effect on a certified election result.

Power evidence

Backup supply and runtime

Named power equipment is rendered exactly as sourced. Missing capacity and runtime remain explicit instead of being inferred from another device or installation.

documented partial

ClearCount power / backup supply

The certified hardware table names the APC SMT-1500C for ClearCount but does not state a ClearCount load-specific runtime.

Supply type
external uninterruptible power supply
Manufacturer
APC
UPS model
SMT-1500C
Capacity
Not specified in reviewed source
Runtime
Not specified in reviewed source
A certified option is not evidence that every installation uses it or that a field battery retains its original capacity.

Deployment evidence

Dated jurisdiction observations

Deployment records remain at their documented grain. A system-level observation does not establish unit components, firmware, change adoption, or power configuration.

not collected

No reviewed deployment observation in this dossier

The source package currently establishes a certified configuration and test history, but no dated jurisdiction-level use record.

Absence from this catalog is not evidence that the system is unused. Deployment claims require a separately reviewed state or local source.