Source-linked configuration dossier
Dominion Democracy Suite 5.17 / ImageCast Central
A separate source-linked dossier for the ImageCast Central configuration: a certified COTS high-speed scanner, workstation, ICC application, removable-media accessories, optional isolated network infrastructure, and documented backup power.
Version evidence
Last sourced observations
“Last” means latest in this reviewed source package, not a live device reading or the newest product-family release.
Certified ICC application
5.17.15.1
This is the final certified application version, not a field reading or evidence of a jurisdiction's current installed version.
- U.S. Election Assistance Commission: Democracy Suite 5.17 Certificate and Scope of Certification Certificate page 1; scope pages 1-3, 7, and 10-13
- Pro V&V, Inc.: Democracy Suite 5.17 Test Report, TR-01-01-DVS-50-01.03 Revision 03; report pages 31-41 and final certified configuration
Certified HiPro firmware support
1.0.1074
This version applies only to the InoTec HiPro scanner alternative and is not a firmware claim for the Canon alternatives or a field-observed scanner.
- Pro V&V, Inc.: Democracy Suite 5.17 Test Report, TR-01-01-DVS-50-01.03 Revision 03; report pages 31-41 and final certified configuration
VSTL + EAC change control
Configuration change history
These are source-linked certification and change records. Field deployment remains separate and unknown unless explicitly documented.
The Pro V&V report records an ICC application update to support InoTec HiPro firmware version 1.0.1074.
- VSTL
- Pro V&V, Inc.
- Dossier relationship
- included in certified 517 configuration
- Field deployment
- unknown
This is certification configuration history. It does not establish that a jurisdiction selected the HiPro alternative or installed the firmware on a field scanner.
- Pro V&V, Inc.: Democracy Suite 5.17 Test Plan, TP-01-01-DVS-50-01.01 Revision 01; test-plan pages 13-17, 22-23, and 37-38
- Pro V&V, Inc.: Democracy Suite 5.17 Test Report, TR-01-01-DVS-50-01.03 Revision 03; report pages 31-41 and final certified configuration
Findings and public status
Tests, limitations, and listing gaps
Neutral finding types replace a generic “bugs” bucket so affected versions and source scope remain visible.
No anomalies or deficiencies reported in the 5.17 certification campaign
Pro V&V reported no anomalies and no deficiencies during the Democracy Suite 5.17 certification campaign; ICC accuracy and integration testing met the stated requirements.
- Pro V&V, Inc.: Democracy Suite 5.17 Test Report, TR-01-01-DVS-50-01.03 Revision 03; report pages 31-41 and final certified configuration
Power evidence
Backup supply and runtime
Named power equipment is rendered exactly as sourced. Missing capacity and runtime remain explicit instead of being inferred from another device or installation.
ImageCast Central power / backup supply
The Colorado guide names the APC SMC1500 and requires enough backup power to complete and save a ballot batch before graceful shutdown.
- Supply type
- external uninterruptible power supply
- Manufacturer
- APC
- UPS model
- SMC1500 Smart-UPS
- Capacity
- 900 W / 1500 VA
- Runtime
- Minimum 15 minutes required by the 5.17-CO guide
- Colorado Secretary of State; Dominion Voting Systems: Democracy Suite ImageCast Central User Guide 5.17-CO::4 PDF pages 6, 39, and 69-71; system parts, power/network requirements, and scanner photographs
Deployment evidence
Dated jurisdiction observations
Deployment records remain at their documented grain. A system-level observation does not establish unit components, firmware, change adoption, or power configuration.
No reviewed deployment observation in this dossier
The source package currently establishes a certified configuration and test history, but no dated jurisdiction-level use record.