Civic Result MapsU.S. election equipment evidence

Source-linked configuration dossier

Dominion Democracy Suite 5.17 / ImageCast X

A source-linked dossier for the ImageCast X ballot-marking device within EAC-certified Democracy Suite 5.17, including certified device alternatives, external UPS options, version observations, Pro V&V results, and EAC-hosted post-certification advisories.

Federal certificate DVS-DemSuite5.17VVSG 1.0VSTL: Pro V&V, Inc.Editorial: published r5
Components12all source-linked
Hardware facts111 explicit unknowns
Change records4field status kept separate
Findings/statuses4version-scoped
Archived sources12local hash verified

Version evidence

Last sourced observations

“Last” means latest in this reviewed source package, not a live device reading or the newest product-family release.

certified assertion2023-03-15

Final report ICX machine-configuration-file identifier

MCF_5.17.15.1_20220920

This is a named MCF identifier in the final test report, not an ICX application version, live readout, or field-installation record.

VSTL + EAC change control

Configuration change history

These are source-linked certification and change records. Field deployment remains separate and unknown unless explicitly documented.

DVS-5.17-ICX-AUTHEAC approved 2023-03-16

The 5.17 modification set added ICX smart-card mutual authentication and secure messaging.

VSTL
Pro V&V, Inc.
Dossier relationship
included in certified 517 configuration
Field deployment
unknown

This is certified configuration history relative to the 5.5-D baseline; it is not evidence that a jurisdiction installed or enabled the change.

DVS-5.17-ICX-DB-ENCEAC approved 2023-03-16

The 5.17 modification set added encryption of election databases on ICX and named companion devices.

VSTL
Pro V&V, Inc.
Dossier relationship
included in certified 517 configuration
Field deployment
unknown

The source describes a bounded certification change, not a general security guarantee, field audit, or claim about every form of stored data.

DVS-5.17-ICX-FUNCTIONSEAC approved 2023-03-16

The 5.17 modification set added ICX support for provisional and Uniform Ballots, additional ballot-barcode information, and configurable on-screen contest columns.

VSTL
Pro V&V, Inc.
Dossier relationship
included in certified 517 configuration
Field deployment
unknown

The record establishes the evaluated 5.17 modification set, not the election features configured or used by a jurisdiction.

DVS-ECO-100936EAC approved 2024-09-24

Pro V&V reviewed updated ICX Prime user-manual procedures for an SSD-firmware update path and classified the documentation change as de minimis with no additional 5.17 testing required.

VSTL
Pro V&V, Inc.
Dossier relationship
post certification change for 517
Field deployment
unknown

The records document a post-certification change path affecting federal 5.17, but do not name the SSD firmware version or establish adoption by any jurisdiction.

Findings and public status

Tests, limitations, and listing gaps

Neutral finding types replace a generic “bugs” bucket so affected versions and source scope remain visible.

test campaign resultnone reported in test campaign

No anomalies or deficiencies were reported in the 5.17 certification campaign

The final Pro V&V report states that no anomalies and no deficiencies were encountered during the D-Suite 5.17 test campaign and recommends certification of the evaluated system.

This statement is limited to that test campaign and evaluated configuration. It is not evidence that every field unit or later operating condition is defect-free.
product advisory noticerestart procedure documented

Touchscreen responsiveness advisory for named ICX Classic versions

A May 2024 EAC-hosted manufacturer notice describes rare startup occasions when a named ICX Classic screen may not respond to touch and provides a power-cycle procedure.

The notice names versions and jurisdictions but does not quantify occurrence or establish that every named jurisdiction or unit experienced the condition.
customer advisory noticedocumentation and ssd firmware update path recorded

ICX Prime SSD advisory and firmware-update documentation path

An August 2024 advisory describes a bounded SSD error during election-project installation or removal, before logic-and-accuracy testing. The linked ECO records updated user-manual procedures for an SSD-firmware update path.

The sources do not establish occurrence during an election, adoption of the update by a jurisdiction, or an SSD model or firmware number. Do not infer a field incident or effect on voted paper records.
customer advisory noticeadvisory issued review guidance

Straight-party and split-ticket selection review advisory

An EAC-hosted customer notice describes a sequence in which previously removed selections can be reapplied after a straight-party selection is manually changed to split-ticket, and recommends review of the summary screen and printed ballot.

The notice does not quantify field occurrence, identify an election outcome effect, or document a software resolution. It is not evidence of fraud, misconduct, or altered votes.

Power evidence

Backup supply and runtime

Named power equipment is rendered exactly as sourced. Missing capacity and runtime remain explicit instead of being inferred from another device or installation.

documented partial

ImageCast X power / backup supply

The SID-21V manual documents the optional battery model, chemistry, voltage, capacity, connector locations, and installation path. It does not publish an election-workload runtime.

Supply type
optional internal rechargeable Li-ion battery
Manufacturer
Not publicly confirmed
UPS model
ACC-BAT-3S1P-01R
Capacity
2,400 mAh typical; 2,215 mAh minimum
Runtime
Not specified in reviewed source
This is an optional model-family component, not evidence that a particular certified or fielded ICX contains the battery or that its present capacity matches the specification.
confirmed

ImageCast X power / backup supply

The Pro V&V ICX configuration lists four external UPS alternatives. The reviewed sources do not state an ICX load-specific capacity or runtime.

Supply type
external uninterruptible power supply
Manufacturer
APC; CyberPower
UPS model
SMT-1500; SMT-1500C; PR1500LCD; PR1500LCD-VTVM
Capacity
Not specified in reviewed source
Runtime
Not specified in reviewed source
Confirmed means the UPS models appear in the reviewed certified or test configuration, not that all are used together, that a jurisdiction selected one, or that battery health and runtime are known.

Deployment evidence

Dated jurisdiction observations

Deployment records remain at their documented grain. A system-level observation does not establish unit components, firmware, change adoption, or power configuration.

not collected

No reviewed deployment observation in this dossier

The source package currently establishes a certified configuration and test history, but no dated jurisdiction-level use record.

Absence from this catalog is not evidence that the system is unused. Deployment claims require a separately reviewed state or local source.