Source-linked configuration dossier
ES&S EVS 6.4.0.0 / DS950
A separate source-linked dossier for the certified DS950 central-count scanner/tabulator, including firmware and hardware revisions, documented motherboard and storage changes, output-transport firmware, central-count cart, and certified UPS alternatives.
Version evidence
Last sourced observations
“Last” means latest in this reviewed source package, not a live device reading or the newest product-family release.
Certified DS950 firmware
4.3.0.0
This is the certified configuration version, not a field reading or unit update record.
- U.S. Election Assistance Commission: EVS 6.4.0.0 Certificate and Scope of Conformance Pages 1-10, especially proprietary components on pages 6-7
- Pro V&V, Inc.: ES&S EVS 6.4.0.0 Certification Test Report TR-01-01-ESS-2023-01.03 Sections 3.2, 3.3, and Tables 4-1 through 4-3
Certified baseline DATAWIN transporter firmware
C60_20221215_0300
This is the firmware named in certified baseline ECO 1151, not a live readout or service record.
- U.S. Election Assistance Commission: EVS 6.4.0.0 Certificate and Scope of Conformance Pages 1-10, especially proprietary components on pages 6-7
VSTL + EAC change control
Configuration change history
These are source-linked certification and change records. Field deployment remains separate and unknown unless explicitly documented.
The scope records an updated Kontron motherboard with DRAM/TPM capabilities, updated PC power supply, second-source smart-card reader, and M.2 hard drive.
- VSTL
- Pro V&V, Inc.
- Dossier relationship
- included in certified evs 6400 configuration
- Field deployment
- unknown
This groups certification modifications and is not a claim that one field service event installed them together.
- U.S. Election Assistance Commission: EVS 6.4.0.0 Certificate and Scope of Conformance Pages 1-10, especially proprietary components on pages 6-7
- Pro V&V, Inc.: ES&S EVS 6.4.0.0 Certification Test Report TR-01-01-ESS-2023-01.03 Sections 3.2, 3.3, and Tables 4-1 through 4-3
ECO 1151 updates DATAWIN transporter firmware so the output tray begins lowering sooner, providing more opportunity for incoming ballots to lay flat if a jam occurs.
- VSTL
- Pro V&V, Inc.
- Dossier relationship
- baseline eco certified with evs 6400
- Field deployment
- unknown
The de minimis ECO is certification history, not evidence of a jam, field update, or election impact.
- U.S. Election Assistance Commission: EVS 6.4.0.0 Certificate and Scope of Conformance Pages 1-10, especially proprietary components on pages 6-7
Findings and public status
Tests, limitations, and listing gaps
Neutral finding types replace a generic “bugs” bucket so affected versions and source scope remain visible.
No anomalies reported in the EVS 6.4.0.0 certification campaign
Pro V&V reported no anomalies during EVS 6.4.0.0 testing and recommended certification after the system met applicable VVSG 1.0 requirements.
- Pro V&V, Inc.: ES&S EVS 6.4.0.0 Certification Test Report TR-01-01-ESS-2023-01.03 Sections 3.2, 3.3, and Tables 4-1 through 4-3
Power evidence
Backup supply and runtime
Named power equipment is rendered exactly as sourced. Missing capacity and runtime remain explicit instead of being inferred from another device or installation.
DS950 power / backup supply
The certified COTS hardware table names two CyberPower UPS alternatives that apply to the DS950.
- Supply type
- external uninterruptible power supply
- Manufacturer
- CyberPower
- UPS model
- OR1500PFCLCD; CP1500PFCLCD
- Capacity
- Not specified in reviewed source
- Runtime
- Not specified in reviewed source
- U.S. Election Assistance Commission: EVS 6.4.0.0 Certificate and Scope of Conformance Pages 1-10, especially proprietary components on pages 6-7
- Pro V&V, Inc.: ES&S EVS 6.4.0.0 Certification Test Report TR-01-01-ESS-2023-01.03 Sections 3.2, 3.3, and Tables 4-1 through 4-3
Deployment evidence
Dated jurisdiction observations
Deployment records remain at their documented grain. A system-level observation does not establish unit components, firmware, change adoption, or power configuration.
No reviewed deployment observation in this dossier
The source package currently establishes a certified configuration and test history, but no dated jurisdiction-level use record.